Water recirculating pump problem

by | Jun 19, 2016 | Plumbing, Problem Solving | 6 comments

Reading Time: 2 minutes
grundfus pump

Grundfus pump

Stump the Plumber

This is another installment in the stump the plumber series.

The situation

I went to look at a kitchen remodeling project and during my evaluation I asked an open question that I always like to explore. “Is there anything else that you would like to discuss, or anything not working?”

They responded that they had a plumber install a Grundfos comfort system (recirculating pump with a timer) that was supposed to have hot water at the sink, but it had never worked.

I figured that they do fail occasionally but I had never had one not work right out of the box.

Naturally I had a look and sure enough “The Plumber”, likely a family friend had but it on the COLD side and set the instructions on top of the GAS water heater near the flu.

The only other way to make a mistake would have been to install it upside down.

I laughed when I thought of how hard the pump had been working all these years pumping water back out into the city water system.

The solution

Other than the instructions had nearly caught on fire, sitting atop the gas water heater, switching the unit to the proper HOT side made a world of difference.

We are men. Instructions are for sissies, right? I call them “distructions” (a combination of directions & instructions) Who knew they had important information in them?

I felt like I had pulled a thorn from the lions paw. Odds are we will be friends for life!

What is all this about recirculating pumps

Recirculating pumps are great, I use one at my home. They recirculate hot water through the system in a continuous loop when you set the timer properly decreasing the amount of wasted water waiting for the hot water to show up.

Here is a link to another post about them.


If you or someone you know could potentially use our services, or just wants to speak to a trustworthy contractor please contact me, you’ll be glad you did.

Your comments are welcome. To ask questions or get more information about proactive residential care, click here to email me directly, or call 208-639-1808

Disclaimer: Some of these images came from the WEB. If they are yours, and you object to them being used, please claim them and I will gladly remove and replace them at once.

Related Posts

The House Whisperer

The House Whisperer

Whisperer was once a derogatory term for someone who gossips back in the mid-1500s; it became more popular in the 1800s, by a guy affectionately called Daniel the Horse-Whisperer Sullivan, who had an uncanny ability to deal with traumatized horses. Then, in 1998, the...

read more
Teaching Gig Ends At 5 Years

Teaching Gig Ends At 5 Years

Joe Levitch just completed a 5-year teaching gig for NARI, my remodeling association, on Zoom. I am so proud of my students and appreciate the opportunity I was given to prepare them for a national exam. I was able to impart some fun with wisdom woven in. Thank you to...

read more

Leave A Comment

6 Comments

  1. jahn Maran

    I have installed a watts recirculating water pump and cannot get to work. It is not the temp sensing unit under the sink since this has already been replaced. I contacted watts and their reply is that this sometimes happens and they have no idea why? Then I contacted Grundfos and received pretty much the same response. The pump is installed correctly and I can hear the motor humming so I know the electrical connection is ok. Can you give me help

    Reply
    • joe

      I can help! Send me a picture or a few and contact me at my email jo*@***********rs.com and we will get it figured out. Must be something silly. Joe

      Reply
  2. Dean

    Joe,

    MY 9-year- old Grundfos hot water recirculating pump suddenly quit sending hot water to the farthest hot water faucet. The pump is installed correctly and the lines into and out of the pump are both hot. So I think the problem is not with the pump. I checked online, and am guessing I need a new bypass valve. Troubleshooting instructions I found online said to turn off the cold valve at the angle vale under the sink and then open the cold side of the faucet and then when the water slows to a trickle, check to see if it is hot–hotter than 90 degrees. I did that, and the water trickle is cold, Do I need a new bypass valve?

    Reply
    • joe

      Dean, the line in and out of the pump will always be hot if it works or not because that is the route the water takes. Make sure the timer is set correctly, several power outages could make the schedule screw up. Can you hear the pump working when it is supposed to be circulating? If you take the pump out and turn it on it will work or not. The bi-metal part under your sink has no moving parts and would be an unlikely culprit. When the pump should be coming on, say in the morning after resting at night, you should be able to sense that warm water is going back in the cold line so your sold faucet should produce warm water for a little bit. (You have probably noticed that over the years) if it is not behaving in that way you likely have a failed pump, hate to say it. Not sure if they are repairable, What is the life expectancy? I have no idea. I have never replaced one. 9 years? certainly out of warranty. Let me know what you figure out. Joe

      Reply
  3. John

    I have a Bell & Gossett recirculation pump and I have to tap it with a hammer to get it to actually start pumping after the aquastat shuts it down. Otherwise it just hits and gets hot.

    Reply
    • joe

      Sounds like the motor needs to be separated from the pump and taken to an electric motor shop for repair / rebuild or worst case, replaced with a new one of the exact same. Not sure if you are doing it yourself. I would think an electrician would be the most helpful in this situation rather than a plumber. From your description it seems like the pump portion is fine. You can always opt to have a plumber help to replace the entire thing. Then you would have a spare to rebuild and have as a backup. Best of luck. Joe

      Reply

Submit a Comment

Your email address will not be published. Required fields are marked *

Yes, I would like to receive emails from Levco Builders LLC. I Boise Idaho. Sign me up!



By submitting this form, you are consenting to receive marketing emails from: Levco Builders LLC. I Boise Idaho. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact

Stay in touch

Sign up to stay in the know. We only share educational content and information, and we don't believe in spam.


By submitting this form, you are consenting to receive marketing emails from: Levco Builders LLC. I Boise Idaho. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact

Recent Posts

Categories

Latest Projects

Master Suite Addition

Master Suite Addition

Master Suite AdditionThe Challenge They came up with a plan drawn by others with several significant errors. One was the size of the addition, and the other was the angle of the trusses. The clients who work remotely turned out to be excellent communicators and...

Dining Room Addition and Kitchen Remodel

Dining Room Addition and Kitchen Remodel

Dining Room Addition and Kitchen RemodelThe Challenge The home had an odd entry room with a coat closet and partition wall in the way. This room was pretty useless and annoying to the client. Then, the kitchen was blocked from the activity in the living room, and the...

Primary Suite Remodel with Deck

Primary Suite Remodel with Deck

Primary Suite Remodel & DeckThe Challenge Inaccurate plans were provided that had to get updated over the course of the project. The project is on a creek so lots of precautions were needed to keep erosion out of it.  The Idea Create a primary suite that is...

Whole House Remodel

Whole House Remodel

Whole House RemodelThe Challenge The home was in the hillside district and in the WUI which means that the home has some extra requirements as far as firesafe and extra structural requirements. There had been an addition done to the house years prior that was not...