As a remodeler in Boise, I am often asked to discuss the possibility of adding Egress windows to existing basements. I realized that the term is foreign to many folks.

What is an egress window?

Egress Windows are  those that meet or exceed a rigid set of dimensions and details that allow save exit in case of emergency. In an area where most contractors will reluctantly take a stab at putting one in for you, Levco boast and brags about installing them.

The primary issue is safety, secondary benefits include increased property value by adding natural light, and adding another legal bedroom.

Challenges include weatherproofing the concrete below the window, cutting concrete without making a mess, and ensuring proper drainage to name a few. We we have devised an excellent combination of materials and procedures that do the job perfectly.

This post has borrowed content from the good folks at Fine Home Building magazine. Although a bit complicated to understand they were able to illustrate the options well.

We have been averaging a dozen Egress Window installations a year over the past several years. Subterranean Egress Windows start at $3,900 a piece with discounts on multiples at the same address.  Each egress window we’ve installed has been a little different. Every case is unique so we insist upon viewing your particular situation before promising.

What type of window should I use?

The opening offered by a double-hung window or a horizontal sliding window would be slightly less than half of the total pane area if the window were fully operable. A casement window offers almost the entire pane area: the most egress for the size of the window. Awning windows are trickier because they often don’t open as wide as casements (if they opened all the way, they’d direct rainwater into the house). Before you buy an awning window for egress purposes, make sure it will satisfy your building inspector.

In addition to the net-clear opening, there are also requirements for sill height, as shown in the drawing. For an egress window in a below-grade basement, a window well with ladders or steps is required. (under certain circumstances)

In our opinion, the cost is a third of the added value to the home and is therefore one of  the most value added remodeling project we can offer. It also is inline with our commitment to suggesting safety oriented features. Egress is not just for subterranean applications either. Building code in Boise Idaho now requires that if you are remodeling and replacing basement windows or any windows for that matter if egress size windows are an option then you must choose to use them. See some of our projects on this site.

Two small hiccups to be aware of

  1. You must get a building permit to do the work
  2. A building permits obligates you to update the smoke detectors and carbon monoxide detectors in your home and deal with lead paint issues.

Here is the 2009 IRC updates:

EMERGENCY ESCAPE AND RESCUE OPENINGS
Both the 2009 IBC and 2009 IRC require emergency escape and rescue openings in sleeping rooms below the fourth floor of a building, and in all basements except those that are used only to house mechanical equipment which are less than 200 square feet in area. The 2009 IBC also contains some exceptions to this for rooms in buildings that are fully equipped with a fire sprinkler system, or for rooms that open directly to a corridor that leads to an exit in two directions.

Typical requirements for sizes, locations, etc., are set forth in Section 1029 of the 2009 IBC and Section R310 of the 2009 IRC. It is important to note that the required opening size of 24 inches high, 20 inches wide and 5.0 or 5.7 square feet in area must be met by “normal” operation of the window. In some cases previous editions of certain ICC legacy codes permitted the removal of a second sash, such as the upper sash in a double hung window, to be counted towards achieving the required opening size. Such an interpretation, however, is no longer applicable under the 2009 IBC and 2009 IRC.

Operable skylights and roof windows are also permitted as emergency escape and rescue openings if they meet the size requirements and the bottom of their opening is within 44 inches of the floor below.

Under the 2009 IRC, the emergency escape and rescue opening must be achieved through normal operation of the window, door or skylight without the use of keys, tools or special knowledge.

Your comments are welcome. To ask questions or get more information about remodeling, click here to email me directly, or call 208-947-7261

If you or someone you know is considering remodeling or just wants to speak to a trustworthy remodeling contractor please contact me, you’ll be glad you did.

Disclaimer: Some of these images came from the WEB. If they are yours, and you object to them being used, please claim them and I will gladly remove and replace them at once.

Disclaimer: Some of these images came from the WEB. If they are yours, and you object to them being used, please claim them and I will gladly remove and replace them at once.

Related Posts

Home Maintinance To Live Longer

Home Maintinance To Live Longer

I love helping people maintain their homes. I write about it, I crow about my successes. There are a million reasons to avoid doing the necessary care and feeding of your home, so I am offering a service that might be right for you. Here is what LevcoCare, our service...

read more
The House Whisperer

The House Whisperer

Whisperer was once a derogatory term for someone who gossips back in the mid-1500s; it became more popular in the 1800s, by a guy affectionately called Daniel the Horse-Whisperer Sullivan, who had an uncanny ability to deal with traumatized horses. Then, in 1998, the...

read more

Leave A Comment

2 Comments

  1. Deanna Jones

    Thanks for the tips! There aren’t any windows in my basement, let alone any means to leave the basement except by going upstairs, so installing egress windows seems like a good way to create a rescue opening. Knowing about the hiccups involved in building an egress window seems good to know to prepare me for any issues I may come across. It seems like the biggest issue I have to face has to do with getting the right permits to install them. Now that I know that I’ll need building permits and to update the smoke and carbon monoxide detectors, I should be able to install new egress windows.

    Reply
    • Joe Levitch

      I find it hard to believe that your basement has no windows. Sounds like a cellar. We typically use and existing window and make it deeper to accommodate the egress qualified one. I would have a pre-construction conference with your inspector if you are planning on doing it yourself to ensure you are not compromising your framing or will be required to install a header. As far wired together smoke and CO monitoring, Our area only requires the upgrade if things are accessible, if not, battery operated radio frequency (RF) units that talk to each other will suffice. How does it work for you in IL?

      Reply

Submit a Comment

Your email address will not be published. Required fields are marked *

Yes, I would like to receive emails from Levco Builders LLC. I Boise Idaho. Sign me up!



By submitting this form, you are consenting to receive marketing emails from: Levco Builders LLC. I Boise Idaho. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact

Stay in touch

Sign up to stay in the know. We only share educational content and information, and we don't believe in spam.


By submitting this form, you are consenting to receive marketing emails from: Levco Builders LLC. I Boise Idaho. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact

Recent Posts

Categories

Latest Projects

Master Suite Addition

Master Suite Addition

Master Suite AdditionThe Challenge They came up with a plan drawn by others with several significant errors. One was the size of the addition, and the other was the angle of the trusses. The clients who work remotely turned out to be excellent communicators and...

Dining Room Addition and Kitchen Remodel

Dining Room Addition and Kitchen Remodel

Dining Room Addition and Kitchen RemodelThe Challenge The home had an odd entry room with a coat closet and partition wall in the way. This room was pretty useless and annoying to the client. Then, the kitchen was blocked from the activity in the living room, and the...

Primary Suite Remodel with Deck

Primary Suite Remodel with Deck

Primary Suite Remodel & DeckThe Challenge Inaccurate plans were provided that had to get updated over the course of the project. The project is on a creek so lots of precautions were needed to keep erosion out of it.  The Idea Create a primary suite that is...

Whole House Remodel

Whole House Remodel

Whole House RemodelThe Challenge The home was in the hillside district and in the WUI which means that the home has some extra requirements as far as firesafe and extra structural requirements. There had been an addition done to the house years prior that was not...